Model |
FR-2204 |
Voltage |
12V |
Capacity |
150Ah |
Dimensions (L x W x H x OH) |
502 x 191 x 397 x 415 mm |
Battery Weight |
54.0 Kg |
Battery packed weight |
56.5 Kg |
Capacity (Duration) |
195~225 Min @ 400W |
20Hr Capacity |
150 Ah |
10Hr Capacity |
126 Ah |
5Hr Capacity |
105 Ah |
Internal Resistance |
9.0 mΩ |
Boost Charging (Starting Rate) |
15.1 A |
Boost Charging (Finishing Rate) |
7.6 A |
Trickle Mode Charging (Minimum) |
126 mA |
Trickle Mode Charging (Maximum) |
504 mA |
500W Backup Duration |
02:40 |
400W Backup Duration |
03:30 |
300W Backup Duration |
04:30 |
200W Backup Duration |
07:30 |
100W Backup Duration |
16:00 |
Cycle Use |
14.40 – 15.0V (-40mV/°C), Maximum Current 22.5A |
Standby Use |
13.60 - 13.80V (-20mV/°C) |
Add |
0.005 Volt per cell for every 1°C below 25°C 0.0028 Volt per cell for every 1°F below 77°F |
Subtract |
0.005 Volt per cell for every 1°C above 25°C 0.0028 Volt per cell for every 1°F above 77°F |
Operating Temperature |
-4°F to 113°F (-20°C to +45°C). At temperatures below 32°F (0°C) maintain a state of charge greater than 60%. |
Self Discharge |
Less than 3% per month at 20°C temperature conditions. |
Rated Capacity at Ambient Temperature |
As per formula: Ct=C27{1+0.0043(t-27)} |
Self-Discharge Standard |
Conforms to IS13369-1992 |