X3 Forth

100 kW

Three Phase - ONGRID INVERTER

Features

IP66 Protection
Cooling Fan
Heat Dessipation
Maximum Efficiency
Maximum MPPT Voltage Range
Maximum 12 MPPTs

Specifications

DC Input

Max. PV array input power [kWp]
150
Max. PV input voltage [V]
1100
Nominal input voltage [V]*
580/600
Startup voltage [V]
200
MPP tracker voltage range [V]
180-1000
No. of MPP trackers
9
Strings per MPP tracker
2
Max. PV input current per MPPT [A]
32
Isc PV Array Short Circuit current per MPPT [A]
46

AC Output

Rated AC output power [kW]
100
Rated AC output current [A]*
151.6/145
Max. AC output apparent power [kVA]
110
Max. AC output current [A]*
166.7/159.5
Nominal AC voltage [V]
220/380, 230/400, 3/N/PE, 3/PE
AC voltage range [V]**
304 ~ 480
Nominal AC frequency/AC frequency range [Hz]**
50/60; ±5
THDi (Rated power) [%]
<3
Power Factor range
0.8 leading ~ 0.8 lagging

System Data

MPPT efficiency [%]
99.9
Max. efficiency [%]
98.6
Ingress protection
IP66
Operating ambient temperature range [°C]
-30~+60 (Derating above 45)
Max. operation altitude [m]
4000 (Derating above 3000)
Relative humidity [%]
0~100
Dimensions [W×H×D] [mm]
985×660×327.5
Weight [kg]
83
Cooling concept
Smart fan cooling
Communication interfaces
RS485 / USB / DRM / PLC(Optional)
Optional monitoring dongle
Pocket WiFi/LAN/4G
Display
LCD(16x2, optional)/LEDx4

Protection

Over/under voltage protection
YES
DC isolation protection
YES
Grid monitoring
YES
DC injection monitoring
YES
Residual current detection
YES
Anti-islanding protection
YES
String fault detection
YES
SPD (DC/AC)
Type II / Type II
Arc-fault circuit interrupter(AFCI)
Optional
AC terminals over temperature detection
YES
AC auxiliary power supply(APS)
Optional
Power line communication(PLC)
Optional

Downloads

Datasheet - icon

01

Datasheet & Specs

Quick Installatioin Guide - icon

02

Quick Installation Guide

User manual - icon