5KW | 10KW | 15KW | |
---|---|---|---|
Max. PV array input power [Wp] |
10000 | 20000 | 30000 |
Max. PV input voltage [V] |
1000 | ||
Nominal input voltage [V]* |
640 | ||
Startup voltage [V] |
150 | ||
MPP tracker voltage range [V] |
120~980 | ||
No. of MPP trackers / Strings per MPP tracker |
2(1/1) | 2(1/1)① | 2(2/1) |
Max. PV input current [A] |
16/16 | 16/16① | 32/16 |
Isc PV Array Short Circuit current [A] |
20/20 | 20/20① | 40/20 |
5KW | 10KW | 15KW | |
---|---|---|---|
Rated AC output power [W] |
5000 | 10000 | 15000 |
Rated AC output current [A]* |
7.6/7.3 | 15.2/14.5 | 15.2/14.5 |
Max. AC output apparent power [VA] |
5500 | 11000 | 15000 |
Max. AC output current [A] |
8.0 | 16.0 | 22.7 |
Nominal AC voltage [V] / AC voltage range [V]** |
220/380V, 230/400V, 3/(N)/PE; (95-285V)* | ||
Nominal AC frequency / AC frequency range [Hz]** |
50/60; ±5 | ||
THDi (Rated power) [%] |
<3 | ||
Power Factor range |
0.8 leading ~ 0.8 lagging |
5KW | 10KW | 15KW | |
---|---|---|---|
Max. efficiency [%] |
98.3 | ||
Euro efficiency [%] |
97.8 | ||
Standby consumption (night) [W] |
<3 | ||
Ingress protection |
IP66 | ||
Operating ambient temperature range [°C] |
-30~+60 (Derating above 45) | ||
Max. operation altitude [m] |
4000 (Derating above 3000) | ||
Relative humidity [%] |
0~100 | ||
Typical noise emission [dB] |
<30 | <45 | <50 |
Storage temperature [°C] |
-30~+60 | ||
Dimensions [W×H×D] [mm] |
342*434*144.5 | 342*434*156 | |
Weight [kg] |
15.5 | 17 | 18 |
Cooling concept |
Natural cooling | Smart fan cooling | |
Communication interfaces |
USB/RS485/DRM, Optional: Meter | ||
Optional monitoring dongle |
Pocket WiFi / LAN / 4G | ||
Display |
2 x LED + LCD(16 x 2) / APP |
5KW | 10KW | 15KW | |
---|---|---|---|
Over/under voltage protection |
YES | ||
DC isolation protection |
YES | ||
DC reverse protection |
YES | ||
Grid monitoring |
YES | ||
DC injection monitoring |
YES | ||
Back feed current monitoring |
YES | ||
Residual current detection |
YES | ||
Anti-islanding protection |
YES | ||
Over temprature protection |
YES | ||
SPD (DC/AC) |
Type II / Type II | ||
Arc-fault circuit interrupter(AFCI) |
Optional | ||
AC auxiliary power supply(APS) |
Optional |