Infineon Reborn

PV 3200

2.6KW HYBRID INVERTER

Features

Upgraded MPPT Chip Set
Control with Wifi
Anti Dust Kit
80A Max PV Charging
Li-ion Battery Compatible
Pure Sine Wave

Specifications

Inverter Mode

Rated Output Power
3200VA / 3000W
Output Voltage Waveform
Pure Sine Wave
Output Voltage Regulation
230VAC ±5%
Output Frequency
50Hz
Peak Efficiency
94%
Overload Protection
5s@≥150% Load
10s@100%~150 Load
Surge Capacity
2x Rated Power For 5s
Nominal DC Input Voltage
24Vdc
Cold Start Voltage
23.0Vdc
High DC Recovery Voltage
29Vdc
High DC Cut-Off Voltage
30Vdc
No Load Power Consumption
35W

Utility Charging Mode

Charging Algorithm
3-Step
AC Charging Current (Maxinum)
60A (@V1/P = 230Vac)
Bulk Charging Voltage Flooded Battery
29.2
Bulk Charging Voltage AGM/Gel Battery
28.2
Floating Charging Voltage
27Vdc

MPPT Solar Charging Mode

Maximum PV Array Power
3000W
Nominal PV Voltage
240Vdc
PV Array MPPT Voltage Range
30Vdc~400Vdc
Max PV Array Open Circuit Voltage
400Vdc
Maximum Charging Current
80A

Line Mode

Input Voltage Waveform
Sinusoidal (Utility or Generator)
Nominal Input Voltage
230Vac
Low Loss Voltage
170Vac ±7V (UPS)
90Vac ±7V (Appliances)
Low Loss Return Voltage
180Vac ±7V (UPS)
100Vac ±7V (Appliances)
High Loss Voltage
280Vac±7V
High Loss Return Voltage
270Vac±7V
Maximum AC Input Voltage
280Vac
Nominal Input Frequency
50Hz / 60Hz (Auto Dectection)
Low Loss Frequency
46±1Hz
Low Loss Return Frequency
47±1Hz
High Loss Frequency
54±1Hz
High Loss Return Frequency
53±1Hz
Output Short Circuit Protection
Circuit Breaker
Efficiency (Line Mode)
>95% (Rated R Load, Battery Full Charged)
Transfer Time
10ms For UPS
20ms For Applicance

General

Safety Certification
CE
Operating Temperature Range
-10˚ C to 50˚ C
Storage Temperature
-15˚ C to 60˚ C
Humidity
5% to 95% Relative Humidity (Non-Condencsing)
Dimensions (D*W*H) mm
390*270*100
Net Weight (KG)
5.4

Downloads

Datasheet - icon

01

Datasheet & Specs

User Manual - icon

02

User Manual